IPAF has released new technical guidance on major inspections of mobile elevating work platforms (MEWPs) aimed at keeping equipment safe beyond the manufacturer’s design life.
The guidance document outlines a major inspection scheme to validate structural integrity and functionality of critical and functionality of critical components of a MEWP. Such a scheme may be undertaken to determine if a machine is within safe design and use criteria beyond the manufacturer’s design life. Design life is defined as the duration determined by the manufacturer for which a structure or a structural component may be used for its intended purpose with recommended maintenance.
“MEWPs are safe by design and constructed to set criteria as defined by national and international standards dependent on which country/continent they are intended to be first put into service,” explained IPAF techinical & safety executive Chris Wrath. “The growing demand around the world for second-hand machines and the retention of machines in some rental fleets has led to the use of MEWPs beyond the original design life. We need to recognise that there are machines in use which i) have been in service for 10 years or more, yet may not have reached their design life with regard to usage, and ii) have reached their design life prior to 10 years because of intensive usage or use in severe operating environment. This is where the new guidance comes in.”
The document reiterates that equipment owners shoudl fulfil their legal obligations and ensure that MEWPs are maintained in good repair and safe working order by implementing regular inspection and maintenenance programmes in accordance with local, state, or federal regulations, legislation, directives, standards and manufacturer’s requirements. These may include: pre-use inspection; interim, frequent or periodic inspections; and six-monthly or annual inspection / examination by a competent person.
“The harsher the operating environment, the more frequent the inspection should be,” said Chris Wraith. “Depending on the frequency of use and severity of the operating environment, planned inspections should be carried out at a frequency to enable the MEWP to be kept in a safe and satisfactory condition. ”
The document thus proposes that a MEWP should undergo a major inspection within 10 years after having been originally put into service and subsequently every 5 years after that (e.g. 10, 15, 20 years old).
The major inspection scheme can also be used to assist owners in determining if a MEWP is within safe design and use criteria when they: i) acquire a machine with insufficient service, maintenancehistory and inspection records or ii) suspect a MEWP to have been exposed to exceptional circumstances which may have affected the structural integrity of critical components, thus jeopordising the safe use.
For more informtion on the new guidance from IPAF please contact our offices on 0800 085 3709 and ask for a copy.